MELSEC-F series High-Speed Counting
Using high speed counters, high speed signals from encoder ans sensors
can be counted.
Because FX PLC has built-in high performance high speed counters, high
speed control is possible with a simple program. A high speed counter
block with hardware comparator is also available.
High speed counter block/adapter
|
Model
(Number of channels) |
Type |
Highest response
frequency |
Hardware comparison
output function |
2-phase counter
edge count function |
Applicable FX PLC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FX
3S |
FX
3G |
FX
3U |
FX
3GC |
FX
3UC |
||||||||||
|
FX2N-1HC
(1 ch)
|
1-phase
1-count |
Max. 50 kHz | ○ | - | × | × |
○
Max. 8 units |
× |
*2*3
○ Max. 8 units |
|||||
|
1-phase
2-count |
Max. 50 kHz | |||||||||||||
|
2-phase
2-count |
1 edge count:
Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz |
○ | ||||||||||||
|
FX3U-2HC
(2 ch)
|
1-phase
1-count |
Max. 200 kHz | ○ | - | × | × |
○
Max. 8 units |
× |
*2
○ Max. 4 units |
|||||
|
1-phase
2-count |
Max. 200 kHz | |||||||||||||
|
2-phase
2-count |
1 edge count:
Max. 200 kHz 2 edge count: Max. 100 kHz 4 edge count: Max. 50 kHz |
○ | ||||||||||||
|
FX2NC-1HC
(1 ch)
|
1-phase
1-count |
Max. 50 kHz | ○ | - | × | × | × | × |
*3
○ Max. 8 units |
|||||
|
1-phase
2-count |
Max. 50 kHz | |||||||||||||
|
2-phase
2-count |
1 edge count:
Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz |
○ | ||||||||||||
|
FX3U-4HSX-ADP
(4 ch)
|
1-phase
1-count |
Max. 200 kHz | × | ○ | × | × |
*1
○ Max. 2 units |
× | × | |||||
|
1-phase
2-count |
Max. 200 kHz | |||||||||||||
|
2-phase
2-count |
1 edge count:
Max. 100 kHz 4 edge count: Max. 100 kHz |
|||||||||||||
- *1 When used together with analog or communication adapters, function expansion board is required.
- *2 When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
- *3 FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
Built-in high speed counter function (high speed input adapter function)
FX3S Series PLC
| Type |
Counter No.
Highest response frequency * |
Max. response
frequency when high speed processing instruction is used * |
Supported high speed processing instructions |
High
speed counter move |
2 phase
counter multi- count function |
FX3U-4HSX-ADP
max. response frequency (FX3U only) |
|||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
When
high speed comparison SET/RESET is used |
When
high speed band comparison HSZ is used |
High
speed comparison SET |
High
speed comparison RESET |
High
speed band comparison |
Counter
interrupt |
High
speed table comparison |
|||||
|
1-
phase 1- count |
C235,
C236, C241 Max. 2 pts: Max. 60 kHz |
overall frequency
60 kHz |
○ | ○ | ○ | × | × | × | - | × | |
|
C237 to C240,
C242 to C245 Max. 4 pts: Max. 10 kHz |
|||||||||||
|
1-
phase 2- count |
C246
Max. 1pt: Max. 60 kHz |
||||||||||
|
C247,
C248, C248(OP) C249, C250 Max. 2 pts: Max. 10 kHz |
|||||||||||
|
2-
phase 2- count |
C251
Max. 1pt: Max. 30 kHz |
× | |||||||||
|
C252,
C253, C253(OP) C254, C255 Max. 2 pts: Max. 5 kHz |
|||||||||||
- * Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.
FX3G, FX3GC Series PLC
| Type |
Counter No.
Highest response frequency * |
Max. response
frequency when high speed processing instruction is used * |
Supported high speed processing instructions |
High
speed counter move |
2 phase
counter multi- count function |
FX3U-4HSX-ADP
max. response frequency (FX3U only) |
|||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
When
high speed comparison SET/RESET is used |
When
high speed band comparison HSZ is used |
High
speed comparison SET |
High
speed comparison RESET |
High
speed band comparison |
Counter
interrupt |
High
speed table comparison |
|||||
|
1-
phase 1- count |
C235,
C236, C238, C239, C241 Max. 4 pts: Max. 60 kHz |
overall frequency
60 kHz |
○ | ○ | ○ | × | × | × | - | × | |
|
C237,
C240, C242 to C245 Max. 2 pts: Max. 10 kHz |
|||||||||||
|
1-
phase 2- count |
C246,
C248(OP) Max. 2 pts: Max. 60 kHz |
||||||||||
|
C247 to C250
Max. 2 pts: Max. 10 kHz |
|||||||||||
|
2-
phase 2- count |
C251,
C253(OP) Max. 2 pts: Max. 30 kHz |
× | |||||||||
|
C252 to C255,
C254(OP) Max. 2 pts: Max. 5 kHz |
|||||||||||
- * Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.
FX3U, FX3UC Series PLC
| Type |
Counter No.
Highest response frequency * |
Max. response
frequency when high speed processing instruction is used * |
Supported high speed processing instructions |
High
speed counter move |
2 phase
counter multi- count function |
FX3U-4HSX-ADP
max. response frequency (FX3U only) |
||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
When
high speed comparison SET/RESET is used |
When
high speed band comparison HSZ is used |
High
speed comparison SET |
High
speed comparison RESET |
High
speed band comparison |
Counter
interrupt |
High
speed table comparison |
||||||
|
1-
phase 1- count |
C235 to C240
Max. 6 pts: Max. 100 kHz |
40 kHz |
40-
(Number of times of use of instruction) |
○ | ○ | ○ | ○ | ○ | ○ | - | 200 kHz | |
|
C244(OP),
C245(OP) Max. 2 pts: Max. 10 kHz |
10 kHz | 200 kHz | ||||||||||
|
C241 to C245
Max. 3 pts: Max. 40 kHz |
40 kHz | - | ||||||||||
|
1-
phase 2- count |
C246,
C248(OP) Max. 2 pts: Max. 100 kHz |
40 kHz | 200 kHz | |||||||||
|
C247 to C250
Max. 2 pts: Max. 40 kHz |
40 kHz | - | ||||||||||
|
2-
phase 2- count |
C251,
C253 Max. 2 pts: Max. 50 kHz (1 edge count, 4 edge count) |
1 edge count | 40 kHz | ○ | 100 kHz | |||||||
| 4 edge count | 10 kHz |
(40-
Number of times of use of instruction)÷4 |
||||||||||
|
C252,
C253(OP), C254, C255 Max. 2 pts: Max. 40 kHz |
1 edge count | 40 kHz |
40-
(Number of times of use of instruction) |
- | ||||||||
| 4 edge count | 10 kHz |
(40-
Number of times of use of instruction)÷4 |
||||||||||
- * Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.