Extension power supply module
| Model | Specifications | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX5-1PSU-5V |
Power supply for FX5 extension module
Internal 5 V DC: 1.2 A *1 Internal 24 V DC: 0.3 A *1 |
○ (AC power supply type)
Up to 2 modules *3 |
× |
○ (AC power supply type)
Up to 1 module |
× |
|
FX3U-1PSU-5V |
Power supply for FX3 extension module
Internal 5 V DC: 1 A *1 Internal 24 V DC: 0.3 A *1 |
*2
○ (AC power supply type) Up to 2 modules *3 |
× | × | × |
|
FX5-C1PS-5V |
Power supply for FX5 extension module
[Output current] 5 V DC: 1200 mA *1 24 V DC: 625 mA *1 |
*4
|
○
Up to 2 modules |
*4
|
× |
- *1 Maximum output current depends on the ambient temperature.
- *2 When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
- *3 Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
- *4 When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.
Connector conversion module
| Model | Specifications | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX5-CNV-IF |
Connector conversion module used from FX5 (extension cable
type)
to connect FX5 (extension connector type) extension modules. Control power: not consumed |
○
Up to 1 module |
× |
○
Up to 1 module |
× |
|
FX5-CNV-IFC |
Connector conversion module used from FX5 (extension
connector type)
to connect FX5 (extension cable type) extension modules. Control power: not consumed |
× |
○
Up to 1 module |
× | × |
Connector conversion adapter
| Model | Specifications | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX5-CNV-BC | Connector conversion adapter |
○
Up to 1 module |
○
Up to 1 module |
○
Up to 1 module |
× |
Extension cable
| Model | Length | Application | Compatible CPU module | ||||
|---|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | ||||
|
FX5-30EC | 0.3 m | Extension cable for extension module |
○
Up to 1 module |
○
Up to 1 module |
○
Up to 1 module |
× |
| FX5-65EC | 0.65 m | ||||||
Bus conversion module
| Model | Specifications | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX5-CNV-BUS |
Bus conversion FX5 (extension cable type) -> FX3
extension
Control power: 5 V DC 150 mA (supplied from PLC) |
○
Up to 1 module |
*1
○ Up to 1 module |
× | × |
|
FX5-CNV-BUSC |
Bus conversion FX5 (extension connector type) -> FX3
extension
Control power: 5 V DC 150 mA (supplied from PLC) |
*2
○ Up to 1 module |
○
Up to 1 module |
× | × |
- *1 FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
- *2 FX5-CNV-IF is necessary to connect to FX5U.
Terminal modules
Terminal modules are used to convert connector-type I/O terminals
into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input
or output, capturing of AC input signals and format conversion into
the relay/transistor/triac output can be performed.
| Model |
No. of input
points |
No. of output
points |
Function | |
|---|---|---|---|---|
|
FX-16E-TB | 16 input points or 16 output points |
Directly connected to the I/O terminal of PLC.
Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring. |
|
| FX-16E-TB/UL | ||||
|
FX-32E-TB |
32 input points, 32 output points, or
16 input points and 16 output points |
||
| FX-32E-TB/UL | ||||
|
FX-16EYR-TB | - | 16 points | Relay output type |
| FX-16EYR-ES-TB/UL | ||||
| FX-16EYS-TB | Triac output type | |||
| FX-16EYS-ES-TB/UL | ||||
| FX-16EYT-TB | Transistor output type (sink) | |||
| FX-16EYT-ES-TB/UL | ||||
| FX-16EYT-ESS-TB/UL | Transistor output type (source) | |||
SD memory card module
| Model | Specifications | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX5-SDCD | SD memory card module | × | × | × |
○
Up to 1 module |
SD memory card
| Model | Specifications | Compatible CPU module | |||||
|---|---|---|---|---|---|---|---|
| Type | Capacity | Number of writes | FX5U | FX5UC | FX5UJ | FX5S | |
| NZ1MEM-2GBSD | SD memory card | 2G bytes | 60,000 times |
○
Up to 1 module |
○
Up to 1 module |
○
Up to 1 module |
*1
○ Up to 1 module |
| NZ1MEM-4GBSD | SDHC memory card | 4G bytes | 100,000 times | ||||
| NZ1MEM-8GBSD | 8G bytes | ||||||
| NZ1MEM-16GBSD | 16G bytes | ||||||
- *1 FX5-SDCD is separately required.
Battery
| Model | Application | Compatible CPU module | ||||
|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | |||
|
FX3U-32BL |
The battery will be used when you desire to retain (latch)
*
the status of the device memory or clock data before a power
failure.
At the time of delivery from a plant, the battery is not built in the CPU module. Please make arrangements if required. |
○
Up to 1 module |
○
Up to 1 module |
× | × |
- * Setting of parameter is required for a power failure retention.
Cable
| Model | Length | Application | Compatible CPU module | ||||
|---|---|---|---|---|---|---|---|
| FX5U | FX5UC | FX5UJ | FX5S | ||||
|
FX-232CAB-1 | 3.0 m |
Use a communication cable to connect a PLC with a personal
computer by RS-232C communication.
FX5-232ADP < − > Personal computer FX5-232-BD * < − > Personal computer |
○ | ○ | ○ | ○ |
- * FX5-232-BD can be connected to the FX5U/FX5UJ/FX5S CPU module.